GYFXBY
GYFXBY
GYFXBY
GYFXBY

GYFXBY

All dielectric non-metallic flat self-supporting single tube optical cable

   Cable Cross-section

   Cable Specification

1. Introduction

Flat optical cable uses several fibers as optical communication medium. Widely used in Metro ODN network especially inside buildings which have multi-floors and room and two parallel fiber reinforced plastics (FRP) are its strength member. The cable is completed with a PE jacket.

2. Fiber color code

No.

1

2

3

4

5

6

Color

Blue

Orange

Green

Brown

Gray

White

No.

7

8

9

10

11

12

Color

Red

Black

Yellow

Violet

Pink

Aqua

3. Optical fiber type and properties

Item

Unit

Specification

G. 652D

Mode field diameter

1310nm

mm

9.2 ± 0.4

1550nm

mm

10.4 ± 0.5

Cladding diameter

mm

124.3~125.0

Cladding non-circularity

%

£1.0

Core concentricity error

mm

£0.5

Coating diameter

mm

245 ± 5

Coating/cladding concentricity error

mm

£10

Cable cut-off wavelength

nm

£ 1260

Attenuation Coefficient

1310nm

dB/km

£0.35

1550nm

dB/km

£0.21

Proof stress level

kpsi

100

Other parameters meet standard ITU-T G.652

Item

Unit

Specification

G. 657A1

Mode field diameter

1310nm

m

9.2 ± 0.4

1550nm

m

10.4 ± 0.5

Cladding diameter

m

124.3~125.0

Cladding non-circularity

%

1.0

Core concentricity error

m

0.5

Coating diameter

m

245 ± 5

Coating/cladding concentricity error

m

10

Cable cut-off wavelength

nm

1260

Attenuation Coefficient

1310nm

dB/km

0.35

1550nm

dB/km

0.21

Macro-bend loss (1 turn, 10mm radius)

1550nm

dB

0.75

1625nm

dB

1.5

Proof stress level

kpsi

100

Other parameters meet standard ITU-T G.657

4. Cable structure and parameter

Item

Contents

Unit

Value

Optical Fiber

/

/

4-12

Strength member

Material

/

FRP (*2)

Diameter

mm

1.6

 

 

Inner jacket

Diameter

mm

3.0±0.1

Material

/

PBT

Filler

/

Jelly

Color

/

Natural

 

Outer jacket

Diameter

mm

8.1(±0.4)×4.5±0.3)

Material

/

PE

Color

/

Black

Tensile performance

Short term

N

1350

Long term

N

400

Crush

Short term

N/100mm

2000

Long term

N/100mm

1000

Cable attenuation

dB/km

SM: 0.4 at 1310nm, 0.3 at 1550nm

Cable weight (Approx.)

kg/km

38

   Characteristic of Optical Cable

1. Min. bending radius

Static: 20 x Cable height
Dynamic: 40 x Cable height

2. Application temperature range

Operation: – 40℃ ~  +70℃
Installation: -30℃ ~ +70℃
Storage/transportation: – 40℃ ~ +70℃

3. Main mechanical & environmental performance test

Item

Test Method

Acceptance Condition

 

 

Tensile Strength IEC 60794-1-2-E1

– Load: Short term tension

– Length of cable:  50m

– Load time: 5min

– Fiber strain £ 0.6%

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

– Load: Long term tension

– Length of cable:  50m

– Load time: 5min

– Fiber strain £ 0.2%

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

 

Crush Test

IEC 60794-1-2-E3

– Load: Short term crush

– Load time: 1min

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

– Load: Long term crush

– Load time: 10min

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

Impact Test

IEC 60794-1-2-E4

– Points of impact: 3

– Times of per point: 1

– Impact energy: 1J

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

Repeated Bending IEC 60794-1-2-E6

– Bending radius: 20 x OD

– No. of cycle: 100

– Load: 20N

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

 

Torsion

IEC 60794-1-2-E7

– Length: 1m

– Twist angle: ±180°

– No. of cycle: 10

– Load: 20N

 

– Loss change £ 0.1dB@1550nm after test.

– No fiber break and no sheath damage.

Kink

IEC 60794-1-2-E10

– Loop diameter:20 x OD

– No kink occurs.

Temperature Cycling IEC 60794-1-2-F1

– Temperature: -40~+70

– Time of each step: 8h

– Number of cycle: 2

– Loss change £ 0.5dB@1550nm.

– No fiber break and no sheath damage.

 

Water penetration

-Time:24h

-H:1m

-L:3m

 

-No water leakage

   Packing

Optional 2Km 3Km 4Km  5Km

Get In Touch With Our Experts

Tell us your business needs, and we will find the perfect solution.